Air & TCLP Methods List

  • EPA-Method 5Particulates
  • EPA-Method 201Filter Weighing
  • EPA-Method 17Particulates
  • EPA-Method 6Sulfate Titration: usually there is only one SO2 fraction per run. If breakthrough analysis is needed, there are 2 fractions per run.
  • EPA-Method 8Sulfate Titration – A typical run has a front half fraction called H2SO4, IPA fraction called SO3, and H2O2 fraction called the SO2. The method calls for putting the front half and IPA together for the H2SO4 result. The number of analysis per run is project dependent.
  • EPA-Method 12Lead: if particulate weights are needed, see Method 5.
  • EPA-Method 13AFluoride (Spadns Fluoride Color Test): one fraction per run is typical.
  • EPA-Method 13BFluoride: one fraction per run is typical.
  • EPA-Method 26/26A - 0050Hydrogen Chloride, Hydrogen Bromide, Hydrogen Fluoride, Chlorine, Bromine.
  • EPA-CTM 27Ammonia: the method calls for analyzing impingers 1 & 2 separately to check for NH4 breakthrough.
  • EPA-Method 29 / M-0060Metals and Mercury: Method 29 Metals/ Sb, As, Ba, Be, Cd, Cr, Co, Cu, Pb, Mn, Hg, Ni, P, Se, Ag, Tl, Zn
  • EPA-Method 101Mercury
  • EPA-Method 101AMercury; usually two fractions per run, (KmNO4 and HCL).
  • EPA-Method 104Beryllium: one fraction per run is typical.
  • EPA-Method 105Mercury in Sludge
  • EPA-Method 108Arsenic
  • EPA-Method 202Condensable Particulate Extraction, organic and aqueous fractions determination.
  • EPA-Method 306Total chrome, one fraction per run is typical.
  • EPA-Method 306Chrome (VI) by HPLC: one fraction per run is typical.
  • EPA-Method M-0061Chrome (VI) by HPLC: one fraction per run is typical.
  • EPA-Method CARB-425Chrome (VI) by HPLC: one fraction per run is typical.
  • Ontario Hydro MercuryMercury: High Range - Instrument range 0.002ug/ml or .2 ng/ml, Low Range- Instrument range 0.00005ug/ml or .05 ng/ml
  • EPA-Method SW-7470-AMercury in liquid waste: the detection limit is based on sample matrix and weight.
  • EPA-Method SW-7471AMercury in Solid and Semisolid waste by cold vapor: the detection limit is based on sample matrix and weight.
  • EPA-Method Boiler MACTMercury & Metals: sample preparation (microwave digestion for coal and ash); MACT Metals (As, Be, Cd, Cr, Pb, Mn, Hg, Ni, Se)
  • EPA-Method 1311/6020/7470A/160.3TCLP Metals TCLP Metals (As, Ba, Cd, Cr, Pb, Hg, Se, & Ag)
  • EPA-Method 1311TCLP pH
  • EPA-Method 3051, 3052/6020Metals, Total Dry Weight Basis
  • EPA-Method 6020ICP-MS Total Quant Analyses
  • EPA-Method 5E/415.15E/415.1 – Total Organic Carbon